Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Braz. oral res. (Online) ; 38: e003, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1528147

ABSTRACT

Abstract Resin composites containing surface pre-reacted glass (S-PRG) have been introduced to reduce demineralization and improve remineralization of the tooth structure. However, water diffusion within the material is necessary for its action, which can impair its overall physicomechanical properties over time, including color stability. This study aimed to evaluate the color stability and related degree of conversion (DC) of four resin composites. Discs (6 x 4 mm, n = 5/group) of microhybrid (MH), nanofilled (NF), nanohybrid (NH), and S-PRG-based nanohybrid (S-PRG-NH) composites with two opacities (A2/A2E and A2O/A2D) were prepared. Color (CIELab and CIEDE2000) was evaluated with a spectrophotometer after aging in grape juice (2 x 10 min/10mL/7days). The DC was analyzed by using Fourier transform infrared spectroscopy before and after light-curing. Data were statistically analyzed by using two-way analysis of variance and post-hoc least significant difference tests (p<0.05). In the color stability analysis, the interaction between filler type and opacity was significant (CIELab, p = 0.0015; CIEDE2000, p = 0.0026). NH presented the highest color stability, which did not differ from that of MH. The greatest color alteration was observed for S-PRG-NH. S-PRG fillers also influenced DC (p < 0.05). The nanohybrid resin composite presented favorable overall performance, which is likely related to its more stable organic content. Notwithstanding the benefits of using S-PRG-based nanohybrid resins, mostly in aesthetic procedures, professionals should consider the susceptibility of such resins to color alteration, probably due to the water-based bioactive mechanism of action.

2.
J. appl. oral sci ; 30: e20220082, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1386011

ABSTRACT

Abstract Objectives To analyze the effect of 5 toothpastes containing different percentages of S-PRG fillers compared to NaF toothpaste and NaF varnish on the dentin hydraulic conductance (Lp). Methodology Dentin disks (1.0±0.2 mm thickness) were cut from third molars, and their Lp values were evaluated using Flodec. The specimens were allocated into 7 groups (n=8). The minimum (smear layer) and the maximum (after acid etching) Lp values were recorded. Lp was also assessed after treatment with either a 0wt.%, 1wt.%, 5wt.%, 20wt.%, or 30wt.% S-PRG toothpaste, a NaF toothpaste, or a NaF varnish. Toothpastes were applied by brushing for 15 s, allowing it to settle for 1 min, and rinsing with deionized water. The NaF varnish was applied for 4 min and was removed with a probe. Specimens were exposed to citric acid (6%, pH 2.1, 1 min) and their final Lp was recorded. The pH of all products was recorded (n=3) and specimens from each group were analyzed by Laser Scanning Confocal Microscopy (LSCM). Data were subjected to 2-way repeated measures ANOVA and post-hoc Bonferroni (a=0.05). Results The highest Lp reduction was noticed for the 5wt.% S-PRG toothpaste, NaF toothpaste, and NaF varnish. However, the toothpastes containing 5wt.%, 20wt.%, and 30wt.% of S-PRG were similar to all toothpastes but differed from the NaF varnish. After erosion, all groups retrieved their maximum Lp values, except for the NaF varnish. The LSCM evidenced deposits on the surface of specimens treated with 5%, 20%, and 30% S-PRG-based toothpastes and NaF toothpaste. Even more deposits were observed for the NaF varnish. After the erosive challenge, the deposits were diminished in all groups. Conclusion Toothpastes containing 5wt.%, 20wt.%, and 30wt.% of S-PRG fillers behaved similarly to a conventional NaF toothpaste, even after an erosive challenge. The NaF varnish promoted better reduction of the Lp, but its effect was also diminished after erosion.

3.
Braz. dent. sci ; 25(2): 1-10, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1367388

ABSTRACT

Objective: The aim of this study was to evaluate the effect of STMP as biomimetic analog of dentin matrix on the dentin bond strength submitted to artificial cariogenic challenge over time. Material and Methods: The total number of teeth used in the experiment was 60 teeth, which were divided into 6 groups (n = 10). Of these total amount, 10 teeth were not submitted to the artificial cariogenic challenge (ACC), serving as control group (Sound Dentin - SD) while the other 50 were submitted to an ACC (7d/37ºC), being treated with treatment solutions according to each group: SD- deionized water/sound dentin, CD- deionized water/ artificial caries dentin, GIII- STMP, GIV- STMP + Ca(OH)2, GV- STMP + NaF, and GVI- NaF. After treatments (24h), the specimens were restored (Adper Single Bond Universal + Filtek Z250), to obtain resin­dentin sticks with a cross sectional area of 0.8mm2, approximately. Two-third of these sticks were stored in artificial saliva (37°C) for analyzes after 6 and 12 months. The 1/3 remains were subjected to µTBS test (baseline). Data were analyzed by two-way ANOVA and Tukey tests (p<0.05). Results: In general, the highest µTBS values were obtained in sound condition (SD), while the artificial caries condition (CD) determined minimum values. Groups treated with NaF (with or without STMP- GV and GVI) were not able to improve adhesion over time. Only the use of STMP + Ca(OH)2(GIV) improved the µTBS compared to the others caries-challenged dentin after 1 year. The adhesive failure pattern was predominant in all time. Conclusion: The use of the STMP associated with Ca(OH)2 seems to be a viable therapeutic strategy conciliating the biomimetizing capacity to the adhesive process satisfactorily even its performance is not superior to initial condition (AU)


Objetivo: O objetivo deste estudo foi avaliar o efeito do STMP como análogo biomimético da matriz dentinária na resistência de união à dentina submetida a desafio cariogênico artificial ao longo do tempo. Material e Métodos:foram utilizados um total de 60 dentes neste experimento, os quais foram divididos em 6 grupos (n = 10). Desse total, 10 dentes não foram submetidos ao desafio cariogênico artificial (DCA), servindo como grupo controle (Dentina Hígida - DH) enquanto os outros 50 foram submetidos ao DCA (7d / 37ºC), sendo tratados com soluções de tratamento específicas para cada grupo: DH- água deionizada / dentina hígida, DC- água deionizada / dentina submetida ao DCA, GIII- STMP, GIV- STMP + Ca(OH)2, GV- STMP + NaF e GVI- NaF. Após os tratamentos (24h), os corpos-de-prova foram restaurados (Adper Single Bond Universal + Filtek Z250), para obtenção de palitos de resina-dentina com área transversal de aproximadamente 0,8mm2. Dois terços desses palitos foram armazenados em saliva artificial (37°C) para análises após 6 e 12 meses. Os outros 1/3 foram submetidos ao teste µTBS (baseline). Os dados foram analisados por ANOVA a dois fatores e testes de Tukey (p <0,05). Resultados:Em geral, os maiores valores de µTBS foram obtidos em condição hígidas (DH), enquanto a condição subtmetidas ao DCA determinou os menores valores. Os grupos tratados com NaF (com ou sem STMP associado -GV e GVI) não foram capazes de melhorar a resistência de união, ao longo do tempo. Somente o uso de STMP + Ca (OH)2(GIV) melhorou o µTBS em comparação com as outras condições desafiadas por cárie após 1 ano. O padrão de falha adesiva foi predominante em todos os tempos. Conclusão: O uso do STMP associado ao Ca (OH)2 parece ser uma estratégia terapêutica viável conciliando a capacidade biomimetizante ao processo adesivo de forma satisfatória mesmo que seu desempenho não seja superior à condição inicial.(AU)


Subject(s)
Humans , Protease Inhibitors , Dentin-Bonding Agents , Dentin
4.
Braz. dent. j ; 30(6): 592-598, Nov.-Dec. 2019. tab, graf
Article in English | LILACS | ID: biblio-1055449

ABSTRACT

Abstract This study aimed to evaluate the polymerization properties of bulk-fill materials (low and high-viscosity) by using high-intensity continuous light and intermittent photo-activation in terms of polymerization shrinkage stress and degree of conversion (DC). The following Bulk-fill and Conventional nanofilled resin composites were evaluated: Filtek Z350XT Flow (3M/ESPE), SureFil SDR Flow (Dentsply), Filtek Bulk Fill Flow (3M/ESPE), Filtek Z350XT (3M/ESPE) and Filtek Bulk Fill Posterior (3M/ESPE). A LED device (DB 685, Dabi Atlante) was used for both protocols: continuous uniform and intermittent photo-activation (light-on and light-off cycles) with identical radiant exposure (14 J/cm2). The polymerization shrinkage stress (n=6) was evaluated by inserting a single increment of 12 mm3 between two stainless steel plates (6×2 mm) adapted to a Universal Testing Machine (UTM), at different times. Measurements were recorded after photo-activation. The degree of conversion was evaluated by Fourier transformed infrared spectroscope (FTIR) with an attenuated total reflectance (ATR) accessory (n=5). Data were analyzed by three-way ANOVA and Tukey's HSD (α=0.05) tests. Bulk Fill Posterior presented higher shrinkage stress values when photo-activated with the intermittent technique (p<0.05). The intermittent photo-activation increased the degree of conversion for the low-viscosity bulk-fills (p<0.05). Therefore, the use of modulated photo-activation (intermittent) must be indicated with caution since its use can influence the shrinkage stress and degree of conversion of composites, which varies according to the resin formulations.


Resumo O presente estudo teve como objetivo avaliar as propriedades de polimerização de materiais bulk-fill (baixa e alta viscosidade) utilizando luz contínua de alta intensidade e fotoativação intermitente em relação ao estresse de contração de polimerização e grau de conversão (DC). As seguintes resinas compostas Bulk-fill e nanohíbridas convencionais foram avaliadas: Filtek Z350XT Flow (3M/ESPE), SureFil SDR Flow (Dentsply), Filtek Bulk Fill Flow (3M/ESPE), Filtek Z350XT (3M/ESPE) e Filtek Bulk Fill Posterior (3M/ESPE). Um dispositivo de LED (DB 685, Dabi Atlante) foi utilizado nos dois protocolos: fotoativação contínua e intermitente contínua (ciclos de liga e desliga) com exposição idêntica (14 J/cm2). A tensão de contração de polimerização (n=6) foi avaliada através da inserção de um incremento único de 12 mm3 entre duas placas de aço inoxidável (6×2 mm) adaptadas a uma Máquina de Ensaio Universal (UTM), em tempos diferentes. As medições foram registradas após a fotoativação. O grau de conversão foi avaliado por FTIR-ATR (n=5). Os dados foram analisados ​​pelos testes ANOVA a três fatores e teste de Tukey (α=0,05). A resina Bulk Fill Posterior apresentou maiores valores de tensão de contração quando fotoativadas com a técnica intermitente (p<0,05). A fotoativação intermitente aumentou o grau de conversão nas resinas bulk-fill de baixa viscosidade (p<0,05). Portanto, o uso de fotoativação modulada (intermitente) deve ser indicado com cautela, uma vez que seu uso pode influenciar a tensão de contração e o grau de conversão dos compósitos, o que varia de acordo com as formulações da resina.


Subject(s)
Materials Testing , Composite Resins , Viscosity , Polymerization
5.
Braz. dent. sci ; 21(2): 257-265, 2018. ilus
Article in English | LILACS, BBO | ID: biblio-906247

ABSTRACT

This case report illustrates a conservative technique for reintervention on anterior composite restorations in a young patient with composite veneers. The treatment incorporated the use of photos and digital planning to establish a harmonious smile design. In order to conserve the dental tissues, existing resin composites restorations in maxillary anterior teeth were carefully removed to minimize enamel reduction, followed by a study of color and shade of teeth considering factors such as hue, chroma, luminosity, opacity, translucency and light effects. Eight direct veneers were built up with resin composite taking the optical properties of the material into account and their influence on the thickness of the layers that create specific light effects when superimposed on each other. To obtain excellent results with a predictable working protocol, nanohybrid composite systems facilitate good aesthetics, avoiding more invasive treatment in an economic manner.(AU)


O presente relato de caso ilustra uma técnica conservadora para a re-intervenção em restaurações diretas de resina composta em pacientes jovens. O tratamento consistiu em fotos e planejamento digital para obtenção de um desenho digital do sorriso individual e harmonioso. De acordo com os princípios de máxima conservação da estrutura dentária, as restaurações existentes nos dentes superiores anteriores foram criteriosamente removidas para minimizar a redução do esmalte, seguido do estudo de cor e sombra dos dentes considerando fatores como matiz, croma, valor, opacidade, translucidez e efeitos de luz. Oito facetas diretas foram realizadas em resina composta considerando as propriedades ópticas do material e a influência destas na espessura das camadas de resina para criar efeitos de luz singulares quando sobrepostas. Para a execução de uma odontologia estética e consciente, em associação a um protocolo de trabalho previsível, os sistemas de resinas compostas nanohibridas possibilitam resultados estéticos satisfatórios, evitando tratamentos mais invasivos de maneira economicamente viável.(AU)


Subject(s)
Humans , Composite Resins , Dental Materials , Enamel Microabrasion , Esthetics, Dental , Tooth Bleaching
6.
J. appl. oral sci ; 25(4): 381-386, July-Aug. 2017. tab, graf
Article in English | LILACS, BBO | ID: biblio-893641

ABSTRACT

Abstract Simplified dentin-bonding systems are clinically employed for most adhesive procedures, and they are prone to hydrolytic degradation. Objective This study aimed to investigate the effect of laser diode irradiation on the degree of conversion (DC), water sorption (WS), and water solubility (WSB) of these bonding systems in an attempt to improve their physico-mechanical resistance. Material and Methods Two bonding agents were tested: a two-step total-etch system [Adper™ Single Bond 2, 3M ESPE (SB)] and a universal system [Adper™ Single Bond Universal, 3M ESPE (SU)]. Square-shaped specimens were prepared and assigned into 4 groups (n=5): SB and SU (control groups - no laser irradiation) and SB-L and SU-L [SB and SU laser (L) - irradiated groups]. DC was assessed using Fourier transform infrared spectroscopy with attenuated total reflectance. Additional uncured resin samples (≈3.0 µL, n=5) of each adhesive were also scanned for final DC calculation. For WS/WSB tests, similar specimens (n=10) were prepared and measured by monitoring the mass changes after dehydration/water storage cycles. For both tests, adhesive fluids were dropped into standardized Teflon molds (6.0×6.0×1.0 mm), irradiated with a 970-nm laser diode, and then polymerized with an LED-curing unit (1 W/cm2). Results Laser irradiation immediately before photopolymerization increased the DC (%) of the tested adhesives: SB-L>SB>SU-L>SU. For WS/WSB (μg/mm3), only the dentin bonding system (DBS) was a significant factor (p<0.05): SB>SU. Conclusion Irradiation with a laser diode improved the degree of conversion of all tested simplified dentin bonding systems, with no impact on water sorption and solubility.


Subject(s)
Dentin-Bonding Agents/radiation effects , Lasers, Semiconductor , Polymerization/radiation effects , Reference Values , Solubility/radiation effects , Surface Properties/radiation effects , Reproducibility of Results , Dentin-Bonding Agents/chemistry , Spectroscopy, Fourier Transform Infrared , Statistics, Nonparametric , Dental Cements/radiation effects , Dental Cements/chemistry , Phase Transition/radiation effects , Light-Curing of Dental Adhesives/methods , Curing Lights, Dental , Photochemical Processes/radiation effects
SELECTION OF CITATIONS
SEARCH DETAIL